AI / HPC Rack Solution
AI / HPC Rack · 42U · Liquid-Cooled

The T18 AI / HPC Rack.
Drop 80 kW of density
into your existing DC.

A pre-integrated high-density rack for AI training and HPC workloads: 8–10 dense GPU nodes, direct-to-chip liquid cooling with in-rack CDU, high-power busbar distribution, and 400GbE / NDR InfiniBand fabric — engineered to integrate with your existing chilled-water plant or run standalone via rear-door heat exchanger.

Density
80 kW+
Per rack, sustained · liquid-cooled.
Cooling
DLC / RDHx
Facility CW tie-in or rear-door heat-x.
Fabric
400 GbE
Or NDR InfiniBand · GPU-Direct RDMA.
Integration
Any DC
Works in air-cooled halls with RDHx.
01 — Overview

AI-scale density, integrated into the DC you already have.

Two paths to cooling

The HR-Series can plumb into your existing chilled-water plant via facility water, or run standalone with a rear-door heat exchanger — dropping into an air-cooled aisle without touching the facility loop. Same rack, different manifold.

High-power busbar distribution

A copper busbar runs the full height of the rack, feeding each GPU node via dropdown breakers. No cable spaghetti at 80kW.

400GbE + NDR InfiniBand fabric

Top-of-rack 400GbE spine plus optional NDR InfiniBand for GPU-Direct RDMA workloads. Cabled and validated at factory before it ships.

Regional AI programs

Deployed for GCC sovereign LLM training programs and university research clusters, with regional firmware baseline signed in-region and Dubai engineering ownership.

02 — Configuration & Specification

Engineered to your site.
Documented to the U.

Configurable options are marked red. Contact engineering for special-order variants and turnkey integration.

Enclosure
Height42U · deep chassis (1200mm)
Width800mm
DoorsPerforated front · rear-door heat exchanger option
Cable MgmtIntegrated fiber runners + power drops
Weight1,400 kg fully populated (indicative)
Cooling & Integration
TypeDirect-to-chip liquid · in-rack CDU
CoolantPG25 · closed loop
CDU Capacity80 kW+ per rack · configurable to 120 kW
Facility InterfaceChilled water OR RDHx (self-contained)
Air BackupFront intake blowers for ambient loads
Power
DistributionCopper busbar · full-height
Input3-phase 63A / 100A · configurable
RedundancyDual feed · A + B · downstream breakers
MonitoringPer-node current + facility kWh · streamed to Fabric
Compute & Fabric
Compute Nodes8–10× T18 AI8-HPC (4U) · SXM5
ToR Fabric400GbE · NDR InfiniBand optional
ManagementT18 BMC + Redfish · Fabric integration
SensorsPer-node coolant flow + temperature
03 — Deployment Use Cases

Where the HR-Series earns its footprint.

U.01

Sovereign LLM Training

Foundation model training clusters for regional cloud programs with data residency requirements.

U.02

Multi-Node HPC

CFD, seismic, and molecular dynamics clusters across academic and industrial customers.

U.03

AI Inference at Scale

Batch inference and RAG serving with pooled accelerators.

U.04

Add Density to Existing DCs

Drop HR-Series into air-cooled halls via RDHx — no facility redesign.

U.05

Fine-Tuning Farms

Iterative fine-tuning workloads for enterprise and government tenants.

U.06

Hyperscale Pods

Bespoke pods for hyperscale customers with custom fabric and power topologies.