Enterprise Rack Solution
Enterprise Rack · 42U or 48U · Air-Cooled

The T18 Enterprise Rack.
Scale-up capacity for
the DC you already run.

A pre-integrated 42U or 48U rack solution that drops into your existing data center estate and integrates seamlessly with whatever cooling and power infrastructure you already run — air-cooled aisles or a mixed liquid environment. Commissioned as a single unit inside your DC.

Height
42U / 48U
Standard EIA-310, 600mm or 800mm wide.
Depth
1200mm
Deep chassis + rear cable management.
Cooling
Air / RDHx
Front-to-rear · rear-door heat-x option.
Integration
Any DC
Retrofit into existing air or liquid halls.
01 — Overview

A scale-up rack you commission, not a rack you build.

Drops into your existing hall

The Enterprise Rack is engineered to scale up capacity inside data centers you already operate. It integrates with your existing air-cooling aisles or, via optional rear-door heat exchangers, with your chilled-water plant — no facility redesign required.

Vertically integrated, factory-populated

Every rack ships from Dubai fully populated with T18 R1/R2 servers, S4 storage, top-of-rack networking, intelligent PDUs, structured cabling, and rack-level monitoring. Commission it as a single unit.

One BOM, one firmware, one NOC

Because every component is a T18 platform, the entire rack shares one management surface, one signed-firmware manifest, and one support engineering pool — even inside a mixed-vendor facility.

Regional-ambient certified

Every rack SKU is validated in the T18 thermal chamber for 40°C intake with failed-fan and failed-PSU derating documented in the ops bible.

02 — Configuration & Specification

Engineered to your site.
Documented to the U.

Configurable options are marked red. Contact engineering for special-order variants and turnkey integration.

Enclosure
Height42U or 48U · configurable
Width600mm or 800mm
Depth1200mm (deep chassis + cable manager)
DoorsPerforated front + rear · lockable · RDHx option
Cable MgmtVertical + horizontal · rear tie-off
Cooling Integration
Air CoolingFront-to-rear · standard hot/cold aisle
Rear-Door HXOptional · chilled-water tie-in · up to 40kW / rack
Certified Intake40°C · failed-fan curve documented
AisleHot / cold aisle containment ready
Facility FitRetrofit into any raised-floor or slab-floor DC
Power
PDUs2× intelligent metered · switched option
Input32A or 63A · single or 3-phase
RedundancyDual feed · A + B
MonitoringPer-outlet current, kWh · streamed to Fabric
Population
ComputeT18 R1 (1U) · R2 (2U) · AI8-HPC (4U)
StorageT18 S4 (4U JBOD) · up to 3 per rack
NetworkTop-of-rack 25/100/400GbE
SensorsT18 environmental pod · standard
03 — Deployment Use Cases

Where the ER-42 / ER-48 earns its footprint.

U.01

DC Scale-Up

Add capacity to existing enterprise data centers without redesigning the facility.

U.02

BFSI Core Banking

Pre-integrated core banking racks with sub-microsecond ToR latency and DR replication.

U.03

Government Sovereign

Sovereign-firmware racks for classified programs — retrofit into government DCs.

U.04

Mixed Air/Liquid Halls

Add high-density RDHx racks alongside legacy air-cooled infrastructure.

U.05

Colocation Cabinets

Turnkey cabinets for colocation tenants who need a full rack, not just chassis.

U.06

Regional Aggregation

Telco and enterprise regional aggregation racks with DC power and PTP time-sync.

Ready to spec the ER-42 / ER-48 for your data center?

04 — Complete the Stack

Related solutions.